InTENSity Twin Stim III - appareil TENS et NMES numérique

SKU: OC-3210

90.9500 90.95$

Professionnels de la santé — connectez-vous pour prix spéciaux.

Imprimer ce produit
Icône Consultez nos experts
Ouverture ou expansion d’une clinique?
Consultez nos experts

Description

The InTENSity™ Twin Stim III combines Tens and EMS therapy in this digital device. The Tens has 4 Modes (Burst, Normal, Mod1, Mod 2) and the EMS has 3 modes (Synchronous, Asynchronous and Delay). Device Intensity is 105mA; AC Adapter included.

Electrodes and wires are included.

TENS

Pulse amplitude: Adjustable 0~105mA peak at 1000 ohm Load each channel, 1mA/step
Pulse width: Adjustable 50 - 300us microseconds, 10μS/step
Pulse rate: Adjustable 1 - 150 Hz, 1 Hz/step
Burst (B) rate: Adjusts 0.5 - 5Hz. Pulse width adjusts 50-300uS. Frequency is fixed at 10Hz.
Normal (N): Pulse rate and pulse width are adjustable. Device generates continuous stimulation based on the setting value. Pulse width modulation (M): Pulse width decreases by 60% and then increases back to its original setting in each cycle. Pulse rate (1 - 150Hz), pulse width (50 - 300us) and cycle time (5 - 30 sec) are adjustable.
Pulse rate modulation (M1): Pulse rate decreases by 60% and then increases back to its original setting in each cycle. Pulse rate (1 - 150Hz), pulse width (50 - 300us) and cycle time (5 - 30 sec) are adjustable.

 

NMES

Pulse amplitude: Adjustable 0~105mA peak at 1000 ohm Load each channel, 1mA/step
Pulse width: Adjustable 50 -o 300μS microseconds
Pulse rate: Adjustable 1 - 150 Hz, 1 Hz/step
Contraction time: Adjustable 1- 60 seconds, 1 sec./ step
Relaxation (OFF) time: Adjustable 0 -60 seconds, 1 sec./ step
Ramp time: Adjustable 1 - 6 seconds, 1 sec. / step. The “On” time will increase and decrease in the setting value.
Synchronous (S): Stimulation of both channels occurs synchronously. The “ON” time includes “Contraction”, “Ramp Up” and “Ramp Down” time.
Alternate (A): The Stimulation of the CH2 will occur after the 1st operation of CH1 is completed. In this program, “ON” time includes “Contraction”, “Ramp Up” and “Ramp Down” time. OFF Time should be equal or longer than the “ON” Time
Delay (D): The Stimulation of the CH2 will occur after CH1 is started + Delay Time. ON TIME = Contraction + Ramp up + Ramp down time. OFF Time should be equal or longer than the “ON” Time. Time Delayis adjusts from 1 - 10 seconds.

Vidéo

Prix pour professionnels

En tant que professionnels de la santé, vous avez droit à des prix spéciaux sur notre sélection de produits. Il vous suffit de vous connecter à votre compte ou d'en créer un pour afficher vos prix.