UltraStim Wire Electrodes with White Cloth (various sizes)

Axelgaard

$6.65 - $109.00

Special pricing for healthcare professionals — sign in to view.

UltraStim Wire 2” (5cm) Round, 4/pack
OC-3370-01A
8.85 $8.85
8.85
UltraStim Wire 2” (5cm) Square, 4/pack
OC-3371-01A
8.85 $8.85
8.85
UltraStim Wire 2” x 4” Rectangle, 2/pack
OC-3372-01A
6.65 $6.65
6.65
UltraStim Wire 1.25” (3.2cm) Round, 4/pack
OC-3373-01A
10.35 $10.35
10.35
UltraStim Wire 2.75” (7cm) Round, 4/pack
OC-3374-01A
13.65 $13.65
13.65
UltraStim Wire 2” (5cm) Round, 40/pack
OC-3370-10A
62.95 $62.95
62.95
UltraStim Wire 2” (5cm) Square, 40/pack
OC-3371-10A
62.95 $62.95
62.95
UltraStim Wire 2” x 4” Rectangle, 20/pack
OC-3372-10A
45.95 $45.95
45.95
UltraStim Wire 1.25” (3.2cm) Round, 40/pack
OC-3373-10A
74.95 $74.95
74.95
UltraStim Wire 2.75” (7cm) Round, 40/pack
OC-3374-10A
109 $109.00
109
Icon Get expert advice

Get Expert Advice

For healthcare professionals only
1-800-561-0310
Contact us >

Description

UltraStim® electrodes are made with Axelgaard’s patented multi-layer MultiStick® hydrogel and features Axelgaard’s silver grid pattern, which controls electrical current evenly over the surface of the electrode. The oversize border featured on these electrodes is specially designed to facilitate ease of proper removal. Dynaflex equivalent.

MDALL 72547.

For use with Tens, NMES and IFC.



UltraStim

Recommended for TENS & NMES & IFC
Latex Free Yes

Smart-Connector
Self adjusting connector to adjust to pin variances; Low Profile for better Patient Comfort.

Yes
Thickness 35mm

Multi-Stick Hydrogel
This patented, dual formulation hydrogel provides a
more durable product & greater number of uses than competitive products.

Yes

Clear Film
Provides a moisture barrier so electrodes can be used with moist heat packs.

No
Cloth Backing Yes

Foam Backing
Provides a moisture barrier so electrodes can be used with moist heat packs.

No
Stainless Steel Knit Fabric No
Film with Printed Silver Ink Grid Yes
Conductive Black Film No

 


MultiStick Hydrogel

All Axelgaard electrodes feature patented MultiStick® hydrogel. The formulation of the hydrogel top layer is optimized for bonding to the electrode to prevent delamination, and the bottom layer is specifically formulated for multiple applications to skin. Axelgaard's controlled scrim placement provides consistent structural support. This multi-layer approach ensures the highest quality electrodes in the industry.




How to optimize the life of your re-usable electrodes

The durability of electrodes depends entirely on the application, storage, humidity and care by the user.

Application: Before each electrode’s application, skin must be cleaned with water and soap to remove any lotions, skin oils, make-up, and dead skin. Any debris on the skin will be transferred to the gel of the electrode’s thereby compromising the integrity of its adhesiveness. A clean surface is the most important factor in the number of applications per electrode.

Storage: After every use the electrode must be returned to the “ON” side of the liner and placed in the original, re-sealable package to prevent loss of moisture. The electrodes should be stored at room temperature. Do not store in freezer or refrigerator, leave in extreme heat, submerge in water or leave outside the package.

Care: After usage, if the electrode picks up small amounts of debris you may use a drop of water on your finger to gently rub the debris off the electrode. Do not use soap, alcohol, submerge in water or scrub with an abrasive material.

Pitting: Check for pitting in the hydrogel layer. Once the gel surface is pitted, electric current may sting the patient.

Healthcare Professional Pricing

As professionals in the medical field, you are entitled to special pricing on our product selection. Simply log in to your account or register to view your special pricing.